Philips TUV-260W Equivalent Replacement | UV Lamp

€0.00

Product Overview

**Philips TUV 260W XPT DIM SE UNP/20** is a dimmable high-output UV-C germicidal lamp designed for water disinfection applications within the Philips Dynapower system. Operating at 260 watts, this amalgam lamp produces powerful UV-C radiation at 253.7 nm for effective deactivation of bacteria, viruses, and other microorganisms. The lamp features a G5.4x17q cap base and is part of a complete system including electronic driver with dimming capability down to 60% power level.---

Technical Specifications

Part Number| 928102805112 |
Alternative Part #| 157925 |
Manufacturer| Signify (Philips Lighting) |
System| TUV Dynapower System |
Philips TUV 260W XPT DIM SE UNP/20is a dimmable high-output UV-C germicidal lamp designed for water disinfection applications within the Philips Dynapower system. Operating at 260 watts, this amalgam lamp produces powerful UV-C radiation at 253.7 nm for effective deactivation of bacteria, viruses, and other microorganisms. The lamp features a G5.4x17q cap base and is part of a complete system including electronic driver with dimming capability down to 60% power level.
Power Consumption| 260 W |
Lamp Voltage| 78 V |
Lamp Current (Nom)| 3.4 A |
Useful Life| 12,000 hours |
Cap-Base| G5.4x17q (4 Pin Single Ended) |
Arc Length| 1,440 mm |
UV-C Output| High Output |
Peak Wavelength| 253.7 nm (UVC) |
Depreciation at Lifetime| 15% |
Diameter| 32 mm |
Overall Length| 1,514 mm (59.70") |
Dimming Range| 100% to 60% (via Dynapower driver) |
Wiring| Preheat |
Dynapower System CompatibleDesigned for the Philips Dynapower electronic driver system
High Output260W lamp for powerful UV-C disinfection
DimmableReduce power to 60% for energy savings while maintaining effective disinfection
Amalgam TechnologySpecial amalgam for highest efficiency across wide temperature range
Protective Inside CoatingEnsures constant UV output over complete lifetime
Single Lamp OperationEasy maintenance with single-lamp per driver configuration
Quick Start~20 second start-up time vs 90 seconds for competitors
TUV Dynapower Driver| Operates 230W, 260W, 335W TUV Amalgam XPT lamps |
Extreme ReliabilityAnnual failure rate of less than 1%
Voltage ProtectionProtection against voltage peaks and permanent overvoltage
100% Stress TestingMinimizes 0-hour failures
Energy SavingsImmediate energy savings compared to similar drivers on the market

Product Overview

**Philips TUV 260W XPT DIM SE UNP/20** is a dimmable high-output UV-C germicidal lamp designed for water disinfection applications within the Philips Dynapower system. Operating at 260 watts, this amalgam lamp produces powerful UV-C radiation at 253.7 nm for effective deactivation of bacteria, viruses, and other microorganisms. The lamp features a G5.4x17q cap base and is part of a complete system including electronic driver with dimming capability down to 60% power level.---

Technical Specifications

Part Number| 928102805112 |
Alternative Part #| 157925 |
Manufacturer| Signify (Philips Lighting) |
System| TUV Dynapower System |
Philips TUV 260W XPT DIM SE UNP/20is a dimmable high-output UV-C germicidal lamp designed for water disinfection applications within the Philips Dynapower system. Operating at 260 watts, this amalgam lamp produces powerful UV-C radiation at 253.7 nm for effective deactivation of bacteria, viruses, and other microorganisms. The lamp features a G5.4x17q cap base and is part of a complete system including electronic driver with dimming capability down to 60% power level.
Power Consumption| 260 W |
Lamp Voltage| 78 V |
Lamp Current (Nom)| 3.4 A |
Useful Life| 12,000 hours |
Cap-Base| G5.4x17q (4 Pin Single Ended) |
Arc Length| 1,440 mm |
UV-C Output| High Output |
Peak Wavelength| 253.7 nm (UVC) |
Depreciation at Lifetime| 15% |
Diameter| 32 mm |
Overall Length| 1,514 mm (59.70") |
Dimming Range| 100% to 60% (via Dynapower driver) |
Wiring| Preheat |
Dynapower System CompatibleDesigned for the Philips Dynapower electronic driver system
High Output260W lamp for powerful UV-C disinfection
DimmableReduce power to 60% for energy savings while maintaining effective disinfection
Amalgam TechnologySpecial amalgam for highest efficiency across wide temperature range
Protective Inside CoatingEnsures constant UV output over complete lifetime
Single Lamp OperationEasy maintenance with single-lamp per driver configuration
Quick Start~20 second start-up time vs 90 seconds for competitors
TUV Dynapower Driver| Operates 230W, 260W, 335W TUV Amalgam XPT lamps |
Extreme ReliabilityAnnual failure rate of less than 1%
Voltage ProtectionProtection against voltage peaks and permanent overvoltage
100% Stress TestingMinimizes 0-hour failures
Energy SavingsImmediate energy savings compared to similar drivers on the market